A rainscreen is a type of assembly applied to an exterior wall consisting of an outer layer, inner layer, and a ventilated cavity between the two. These systems have been used extensively in other markets but are relatively new to the US. As codes evolve, and building science advances, rainscreens are becoming a popular way of enclosing buildings. They greatly increase performance while simultaneously enabling designers to achieve new and striking designs....
Magnesium oxide (MgO) products are panelized construction products that can be used as a direct replacement for other panels, such as gypsum, plywood, and OSB. This course aims to provide insight into MgO products, equipping building professionals with the knowledge and tools to select and specify them correctly, which in turn impacts occupant safety. We will also explore their performance characteristics, features, and purported issues, as well as relevant building code provisions and the evaluation process required for product compliance. Finally, we’ll look at the types of testing data for building materials and the importance of using certified products to ensure occupants’ life safety....
View the NEXGEN Building Products Course Library
This course is part of one or more "Course Collections". Click here to view the details.
Bathing facility code compliance does not have to result in an institutional look. Assisted living and healthcare facilities, hospitality installations, universities, multifamily buildings, and large commercial projects all have unique demands, and most require barrier-free, ADA, UFAS, ANSI, California Title 24, or Massachusetts compliant bathing and showering facilities. This course provides an overview of intelligent design solutions that simultaneously address these code requirements and the aesthetic and functional demands of each situation....
View the Bestbath Course Library
This course is part of one or more "Course Collections". Click here to view the details.
Cable railings are a beautifully minimalist way to meet safety requirements without obstructing the view. Learn how to assemble a commercial-grade cable railing with sophisticated fittings engineered to simplify installation, comply with building codes, and reduce overall labor costs....
A growing number of high-rise fire incidents around the world have raised awareness about the fire safety performance of taller structures. Timing for containing a high-rise fire is critical, as high numbers of occupants have limited means of escape. Vertical fire spread along the exterior facade may quickly overwhelm firefighters at ground level, especially if it advances to heights beyond the reach of their ground attack. This course looks at issues surrounding high-rise fires, how they spread, and how following building codes and proper material testing can lessen the risk or impact of these blazes....
View the Owens Corning Course Library
This course is part of one or more "Course Collections". Click here to view the details.
This course reviews the evolution of accessible restrooms and the recent, sudden prominence of universal (or adult) changing tables. We’ll examine how new changes to both the International Building Code® and statewide legislation affect public restroom design, and the profound impact universal changing tables can have on the lives of people with disabilities and their caregivers....
This course explores the below-grade use of polyisocyanurate (POLYISO) insulation to meet energy code and maximize thermal performance of the building foundation. Let us help dispel the myths that have been created relative to POLYISO insulation while discussing its thermal performance, water absorption, and load capacity – the three primary characteristics for below grade insulation. In addition, we will discuss how the insulation can provide protection for the foundation waterproofing system....
View the Rmax - A Division of the Sika Corporation Course Library
This course will provide an overview of resilient design and discuss how resilient design is not covered by typical building codes and standards. The role of masonry construction in meeting resilient design goals is explained, and the inherent properties of masonry that make it resilient are described. There will be examples given in the presentation of resilient design strategies....
Recent changes in North America energy codes for the building envelope include higher insulation R-values, continuous insulation, and continuous air barriers for air leakage control. New, code compliant wall assembly design options may be susceptible to increased moisture sensitivity due to lower drying rates, which are inherent to energy efficient assemblies but could be further impacted by design detailing and materials choices. Improved energy efficiency does not need to come at the expense of the long term performance and durability of buildings. This seminar will address design options and materials choices for energy efficient and durable wall design. Design tools for advanced moisture analysis (WUFI®, Wärme und Feuchte Instationär, or Transient Heat and Moisture Analysis) will be used to show how to predict performance of untested new assemblies, how materials substitution could impact the overall performance of the building envelope, and how design detailing could increase moisture management capabilities....
View the DuPont Performance Building Solutions Course Library
The use of automatic entrances and ICU/CCU doors helps solve the problems associated with both circulation and door openings in healthcare design while providing an aesthetically pleasing solution. Healthcare personnel, patients, security personnel, and visitors are constantly rushing and want instant access. Today people are very conscious of touching surfaces and prefer not to have contact with doors. Other issues that need to be addressed during design are movement of patients and equipment, ADA and building code compliance, security, energy conservation, and sustainability....
The 2024 edition of the International Building Code® (IBC®) contains significant, helpful, and useful updates to fire safety provisions for exterior wall assemblies containing combustible components and combustible exterior wall coverings. Key changes include new and revised defined terms, new provisions clarifying when vertical and lateral flame propagation testing (NFPA 285) is required and provides three (3) prescriptive compliance methods. Several New sections were added for building materials such as Insulated Metal Panel systems (IMPs) and Building Integrated Photovoltaic (BIPV) systems for exterior wall coverings. Additionally, significant reorganization and revisions of Section 104 Duties and Powers of the Building Official were made that provide the building official with more clear guidance and tools to both interpret and enforce the building code. This presentation will combine an overview of fire safety requirements for exterior wall assemblies based on the 2021 IBC with explanations regarding updates that were made to the 2024 IBC....
View the North American Modern Building Alliance Course Library
This course provides a general overview of air barriers- their role in building performance, the material options, and design considerations. Building code requirements and verification testing will be reviewed for an understanding of how to meet or exceed today’s performance requirements. General considerations will also be discussed to aid in selecting the best system and installation methods for specific projects....
Continuous insulation is part of building standards and state and energy codes due to its ability to reduce thermal bridging and the associated heat loss and energy consumption. This course looks at the use of polyisocyanurate as a continuous insulation in Type V and residential construction and its use as a multifunctional envelope component—air barrier, weather-resistive barrier, and vapor retarder—by reviewing code requirements for the building envelope....
View the PIMA - Polyisocyanurate Insulation Manufacturers Association Course Library
PIMA - Polyisocyanurate Insulation Manufacturers Association
A naturally occurring radioactive gas, radon is a silent danger to our health. Colorless and odorless, it enters homes and structures through openings in the foundation and below-grade walls, becoming trapped in basements and other poorly ventilated areas. This course looks at methods of controlling radon, how it is addressed in building codes, the advantages of closed-cell spray polyurethane foam (ccSPF) over other insulation materials, and proper installation techniques....
One hour seminar detailing the use of Expansion Joint Covers. Designed to broaden knowledge of joint movement and proper joint sizing to ensure there is no structural damage or life safety issue. Contains an overview of both interior and exterior Expansion Joint Covers and which are most appropriate for certain conditions. Fire barriers are discussed and what's important to know regarding current testing requirements and how to specify them to meet current building codes....
Lightweight, prefinished, and factory-fabricated insulated metal panels (IMPs) offer building owners a durable, cost-efficient, and easy-to-install roofing system that provides an air barrier, vapor barrier, and insulation all in one product. This course discusses the characteristics of IMPs and the installation process and explains why IMPs are ideally suited for pre-engineered and structural steel buildings. The role of IMPs in a building’s hygrothermal control layers and IMP code compliance are reviewed....
Stairs are an essential component of a movement and wayfinding strategy in a structure and a primary means of egress, exit, and floor-to-floor access in the event of a fire or emergency for buildings with multiple floors or a change in rise. This course discusses stair and egress system design and evaluates why the design and fabrication of pre-engineered steel stairs create safe stair environments that comply with building codes....
View the Pacific Stair Corporation Course Library
This course is part of one or more "Course Collections". Click here to view the details.
Explore specialized materials, code compliance, and the unique environmental demands of mission-critical facilities to optimize energy efficiency and building resilience. Learn about the unique fire risks and environmental demands of data center operations. Evaluate how product solution choices affect energy efficiency, installation, maintenance, and risk management....
3M - Building Protection - Air Barrier, Fire Barrier, and Insulation Moisture Barrier/Jacketing
The increase in building energy efficiency requirements has led to the use of exterior continuous insulation (CI) to improve the performance of the building envelope. This presentation reviews the benefits of polyiso continuous insulation and then examines in detail the NFPA 285 test standard and fire safety requirements of the 2021 International Building Code for the use of polyisocyanurate insulation in exterior walls of commercial buildings (Construction Types I–IV)....
View the PIMA - Polyisocyanurate Insulation Manufacturers Association Course Library
PIMA - Polyisocyanurate Insulation Manufacturers Association
Dual-flush wall-mounted toilets help create modern, stylish bathrooms that strike a balance between sustainable water efficiency, flexible design, and space savings. This course compares this style with other traditional types of toilets, discusses how wall-mounted toilets benefit commercial and residential users, and explains how they satisfy the Americans with Disabilities Act (ADA) and other accessibility and building code requirements....
In the wake of the green movement, combined with rising energy costs, building sustainability has become an important topic. This course examines how foil-faced polyisocyanurate (polyiso) continuous insulation can function as a multiple control layer, providing a building with an air and water-resistive barrier and a thermal control layer. Additionally, this course reviews building codes and standards for meeting the continuous insulation requirements in steel stud building envelope designs, the benefits of using polyiso insulation in wall assemblies, and how polyiso insulation meets NFPA 285 requirements....
View the Rmax - A Division of the Sika Corporation Course Library
Security entrance control is essential to manage the flow of visitor and authorized user traffic through secured or restricted areas. A wide range of products with multiple types of technologies are available, and a host of buzz words describing their operation abound in this industry. Join us as we journey through the range of products, their operation, the level of security they provide, and both building code and ADA compliance. Security entrance control enhances the safety and peace-of-mind for of employees, residents, passengers, customers, visitors, etc. by providing automatic security screening of those who try to enter and exit the secured space. This secured space may be a campus, an entire building, or designated area within the building. Security entrance control occurs at office and residential buildings, healthcare facilities, entertainment complexes, transportation facilities, campuses, shopping locations, and anywhere that people enter and exit. The security entrance combined with credentialing equipment and software that limits use to only authorized personnel, make for a seamless passage into a secure area. Not only do security entrances control access and/or egress, they provide a visual presence that serves as a deterrent. SECURITY IS A MUST IN TODAY’S WORLD....
Locating mechanical and electrical equipment on a roof is often necessary for space and efficiency in a building design. However, it can be challenging to provide a means for safe maintenance access while preserving the roof membrane and structural integrity and not interfering with other rooftop equipment. This course presents the components that comprise rooftop support systems designed to solve these challenges, as well as system design considerations and compliance with the International Building Code® (IBC®) and the International Mechanical Code® (IMC®)....
The use of automatic entrances and ICU/CCU doors helps solve the problems associated with both circulation and door openings in healthcare design while providing an aesthetically pleasing solution. Healthcare personnel, patients, security personnel, and visitors are constantly rushing and want instant access. Today people are very conscious of touching surfaces and prefer not to have contact with doors. Other issues that need to be addressed during design are movement of patients and equipment, ADA and building code compliance, security, energy conservation, and sustainability....
Review the physics of building envelopes, including hygrothermal loads, control layers, climate zones and cladding functions. The importance of control layer continuity at wall, roof and slab connections is studied. We look at how IMPs perform the same functions as multi-component wall systems through the use of panels joints, sealants and an insulating core. Emphasis is placed on the concept of the Perfect/Universal Wall, and how utilizing the proper ordering of wall components can greatly simplify wall design in all climate zones. Energy codes are also touched on, including their impact on the use of Perfect/Universal Wall designs. This course reduces a relatively complex subject to a level that teaches practical concepts for the building designer....
Displaying 133 - 157 of 361 results.
FIRST PREV [83-107] [108-132] [133-157] [158-182] [183-207] NEXT LAST