Vacuum insulation panels (VIPs) offer higher thermal resistance per unit thickness than traditional insulation materials. This means a building envelope can meet the effective R-values for enclosures required by the energy codes without having to increase the thickness of the walls, roof, or floors. This course discusses how VIPs work, why they are effective, and the impact the properties of the materials used to construct a VIP can have on its performance. VIP installations and the latest developments in VIP technology are reviewed to illustrate the advantages of using VIPs as thermal insulation in the design of energy-efficient buildings....
View the Panasonic Industrial Devices, Building Materials Group Course Library
Recent changes in North America energy codes for the building envelope include higher insulation R-values, continuous insulation, and continuous air barriers for air leakage control. New, code compliant wall assembly design options may be susceptible to increased moisture sensitivity due to lower drying rates, which are inherent to energy efficient assemblies but could be further impacted by design detailing and materials choices. Improved energy efficiency does not need to come at the expense of the long term performance and durability of buildings. This seminar will address design options and materials choices for energy efficient and durable wall design. Design tools for advanced moisture analysis (WUFI®, Wärme und Feuchte Instationär, or Transient Heat and Moisture Analysis) will be used to show how to predict performance of untested new assemblies, how materials substitution could impact the overall performance of the building envelope, and how design detailing could increase moisture management capabilities....
View the DuPont Performance Building Solutions Course Library
When daylighting a space, there are endless ways to go about it. With the power of daylight simulation, you can make informed decisions about material selections, placement and opening sizes, as well as building geometries. Modeling allows you to compare multiple designs to see how they will perform, while verifying light levels, potential glare and code compliance. Learn how we can help....
NFPA 285 is defined as: the Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components. NFPA 285 assembly tests are required when exterior non-combustible walls contain combustible components per the International Building Code (IBC). The scope of materials classified by the IBC requiring NFPA 285 testing is increasing. Combined with more stringent energy code requirements, the use of combustible materials is also growing in exterior walls. The most common contributing factors to non-compliance of designs requiring NFPA 285 assembly testing include: −Lack of understanding of applicability of test on exterior wall assemblies. −Recent building and energy code changes causing new triggers for the test. −Lack of understanding of assembly vs. product results for NFPA 285 tests. This seminar will discuss the impact of the NFPA 285 Test on buildings using IBC-2018, the parameters and history of NFPA 285, which building envelope components are combustible and require NFPA 285 testing per IBC, and the paths to NFPA 285 code compliance that a designer can take. These elements all combine to integrate NFPA 285 compliant assemblies into building envelope systems....
View the DuPont Performance Building Solutions Course Library
A roof is a defining feature of a building, but today’s roofs are asked to provide much more than a simple enclosure. Modern roof systems may need to deliver a wide range of benefits – from protecting against severe weather to reducing energy waste to improving occupant well-being and comfort. Each component of the roof system has an important role to play, including the insulation layer. This presentation introduces the key benefits and attributes of polyiso roof insulation products. Topics covered include designing building and energy code-compliant roof assemblies, solving performance challenges like ponding water, and reducing the environmental impacts of buildings with roof systems that contain polyiso insulation products....
View the PIMA - Polyisocyanurate Insulation Manufacturers Association Course Library
PIMA - Polyisocyanurate Insulation Manufacturers Association
Restrooms and other plumbing applications must comply with accessibility regulations, but do you know exactly how to do that? This course is a handy reference that explains what codes and regulations you must satisfy, when those requirements apply to new construction and alterations, and how to select and install fixtures to meet accessibility standards and the requirements of the LEED® v5 for Building Design and Construction and Interior Design and Construction rating systems and the WELL Building Standard™ v2....
View the Zurn | Elkay | Hadrian | World Dryer | Wilkins Course Library
Zurn | Elkay | Hadrian | World Dryer | Wilkins
This course is part of one or more "Course Collections". Click here to view the details.
Understanding building physics is critical to proper building envelope design. Examined here are practical concepts for the building designer, including how cladding systems perform across different climate zones and applications. Environmental control layers and hygrothermal loads are reviewed, as is the concept of perfect/universal wall design. The course focuses on how single-component insulated metal panels (IMPs) function as a perfect/universal wall, simplifying wall system design and installation....
The federal government, more and more states and local jurisdictions are enacting regulations and building codes mandating the installation of solar PV or solar-ready design on new building construction. This will result in an accelerated growth of rooftop solar with an intent to reduce costs and maximize the energy output of solar installations. The key to complying with solar mandates is mastering solar and building integration. This means considering the roof and solar as a single system, as well as non-traditional design elements focused on the anticipation of rooftop solar installations. All structural analysis must include all the system elements and full load path, including solar mounting systems and roof structures. And finally, a look at case studies, storms and testing....
With limited exceptions, the International Building Code® (IBC®) requires testing and compliance with NFPA 285 for exterior wall assemblies of buildings of Types I, II, III, and IV construction containing foam plastic insulation. This course examines three methods for demonstrating that an exterior wall assembly design complies with NFPA 285, including engineering analysis. The course also discusses how and where to locate NFPA 285 information for each compliance method....
View the North American Modern Building Alliance Course Library
Main entrance air curtains are used by architects and engineers in commercial, institutional, and industrial settings to both improve energy efficiency and protect occupant comfort and well-being. This course reviews the research that led to air curtains being approved as an alternative to vestibules in ASHRAE 90.1-2019 and other building codes, as well as how air curtains on main entries contribute to sustainability goals around energy conservation, public health, and indoor air quality....
Security entrance control is essential to manage the flow of visitor and authorized user traffic through secured or restricted areas. A wide range of products with multiple types of technologies are available, and a host of buzz words describing their operation abound in this industry. Join us as we journey through the range of products, their operation, the level of security they provide, and both building code and ADA compliance. Security entrance control enhances the safety and peace-of-mind for of employees, residents, passengers, customers, visitors, etc. by providing automatic security screening of those who try to enter and exit the secured space. This secured space may be a campus, an entire building, or designated area within the building. Security entrance control occurs at office and residential buildings, healthcare facilities, entertainment complexes, transportation facilities, campuses, shopping locations, and anywhere that people enter and exit. The security entrance combined with credentialing equipment and software that limits use to only authorized personnel, make for a seamless passage into a secure area. Not only do security entrances control access and/or egress, they provide a visual presence that serves as a deterrent. SECURITY IS A MUST IN TODAY’S WORLD....
Modular metal panels (MMPs) integrate advanced technology with modern aesthetics, providing high-performance building envelopes that enhance design and durability. This course explores the evolution of MMPs and what distinguishes them from other building products. You will examine the key components that make up the system and its fundamental principles and best practices. Finally, the course demonstrates how these elements combine in real-world applications, showcasing various design options....
An expansion joint is a structural gap designed to accommodate the movement of a building in a controlled manner, preventing damage to the building’s internal and external finishes. Expansion joints run throughout a building in walls, ceilings, and floors. Expansion joint covers provide a covered transition across an expansion opening and remain unaffected by the relative movement of the two surfaces either side of the joint. This course explains how to determine joint movement requirements and how to size a joint. It also discusses the performance of different expansion joint cover systems and the applicable fire protection and building codes....
Falls are responsible for more open wounds, fractures, and brain injuries than any other cause of injury. Photoluminescent (PL) exit path markers have proven to provide safe and quick egress in all light conditions for occupants and fail-safe guidance to first responders entering unfamiliar surroundings in the event of an emergency. This course discusses the benefits of PL safety products and the codes and testing standards related to PL way-finding systems....
View the Ecoglo Inc. Course Library
This course is part of one or more "Course Collections". Click here to view the details.
Understanding the performance of building materials in real-world conditions is key to a successful building design. Recent studies have shown that the commonly reported R-values of polyisocyanurate foams at room temperature may overstate their real-world performance in cooler temperatures, potentially resulting in gaps in designed building enclosure assembly performance and quality. Through a theoretical framework and empirical data, this course shows that optimized polyisocyanurate foam insulation results in better performance, leading to improved energy savings and reduced potential for condensation. Participants are encouraged to explore innovative insulation materials, understand differences between them, and match optimal materials to specific applications while meeting modern construction codes and regulations. By matching the right insulation materials to the application, architects can contribute to energy-efficient and cost-conscious construction practices and help buildings reduce their impact on the environment....
View the DuPont Performance Building Solutions Course Library
This presentation focuses on wind design requirements for commercial low-slope roofing. The presentation covers building code history, ASCE 7, future tornado wind design requirements and agency approvals for wind uplift resistance for low-slope roofing....
Radon is a colorless, odorless gas, a Class A carcinogen, the leading cause of cancer after smoking, and the leading cause of death for nonsmokers. It is found in soil, rock, and groundwater. If radon enters a home through slabs, basements, and crawl spaces, breathing it can lead to illness or even death. This course examines how the gas travels through soil and into structures and the various interception approaches and materials that can be utilized to prevent entry into inhabited spaces. It also highlights building code requirements and language that can assist with ensuring the correct radon interception systems are designed and installed effectively....
Understanding how insulated metal panels comply with fire safety regulations under the code are critical to their proper use in creating highly energy efficient and sustainable buildings. This course takes a relatively complex subject and addresses the most important fire safety related aspects to allow building designers to make an informed decision on the use of these popular cladding systems. We will review how these products have been addressed in the development of the International Building Code, including their applications in both combustible and noncombustible structures as well as single and multi-story construction. The program will conclude with a look at the various third-party product listings, evaluation reports, and engineering judgements used to evidence compliance with the International Building Code....
A rainscreen is a type of assembly applied to an exterior wall consisting of an outer layer, inner layer, and a ventilated cavity between the two. These systems have been used extensively in other markets but are relatively new to the US. As codes evolve, and building science advances, rainscreens are becoming a popular way of enclosing buildings. They greatly increase performance while simultaneously enabling designers to achieve new and striking designs....
Gain an overall understanding of how wind and wind codes affect overhead doors and how these codes help to ensure the health, safety, & welfare of building occupants....
Energy codes at the federal, state, and local levels increasingly focus on reducing energy consumption, saving consumers money, and reducing CO2 emissions. Whether new or recently updated, energy codes play an essential role in the buildings we design, build, and ultimately live, work, and play in. This course examines the lighting requirements and provisions of ASHRAE Standard 90.1-2019 and the 2021 International Energy Conservation Code ® , with a focus on plug and lighting control strategies for energy efficiency....
The need to evaluate thermal bridging in a building’s design and performance has become more prevalent because of the increasing requirements for more energy-efficient buildings. This course provides an introduction to thermal bridging, energy code requirements, and the use of thermal break solutions designed to improve energy efficiency in the building envelope....
Insulating concrete form (ICF) products use a cost-effective and robust structural material option (reinforced concrete) to turn a building envelope into a high-performing thermal, moisture, and air enclosure with disaster resistance and built-in compliance with energy code requirements. As a result of ICF performance, building owners can complete a whole structure with ICFs and reinforced concrete, including intermediate suspended floors, rooftops, and multistory designs. This course examines the advancements in ICF technology and discusses the potential contribution of ICFs to supporting improved sustainability and resilience....
Building fires claim nearly 4,000 lives each year in the U.S. It is the responsibility of building designers to do their utmost to prevent such fires and their accompanying loss of life. Often, the difference between life and death is as simple as a fire door that functions properly. This course focuses on describing how design professionals can reinforce their ability to ensure that fire doors are specified, installed, inspected, and maintained properly and that they meet or exceed all relevant code requirements....
This course is part of one or more "Course Collections". Click here to view the details.
Helps provide the design community with a better understanding of the model energy code requirements for insulation in metal buildings, how codes are changing, including requirements for continuous insulation and air barriers along with considerations when selecting the right insulation....
View the DuPont Performance Building Solutions Course Library
Displaying 153 - 177 of 340 results.
FIRST PREV [103-127] [128-152] [153-177] [178-202] [203-227] NEXT LAST